Air capture hood ACCUBALANCE 8380

Air capture hood ACCUBALANCE 8380

8380

Packaging Unit:

  • Ergonomic design and ultra light weight
  • Measurement of the following parameters possible:
    • Differential pressure, absolut pressure, volume, flow rate
    • Volume / flow rate
    • Air speed with sensor at i.e filter surfaces
    • Temperature (also in liquids) and relative humidity
  • Easy to use software interface
  • Battery use

Packaging Unit: 
€ 2,785.00

Air capture hood ACCUBALANCE 8380

8380

Packaging Unit:


  • Ergonomic design and ultra light weight for easy, one-person operation
  • Measurement of the following parameters possible:
    • Differential pressure, absolut pressure, volume, flow with pitot tube in a duct
    • Volume / flow with hood in air outlets, saftey workbenches
    • Air speed with sensor at i.e filter surfaces
    • Temperature (also in liquids) and relative humidity
  • Easy to use software interface
  • Measurement hoods in various sizes
  • Display of min-, max- and mean values
  • Automatic zero point correction for the pressure sensor
  • Battery use


Technical data:


Air speed:

  • Pitot tube: 0.125 to 78,0 m/s 
  • Pressure probe: 0.125 to 25,0 m/s 
  • Matrix probe: 0.125 to 12,5 m/s 
  • Accuracy: ±3 % of measurement value or ±0.04 m/s at speed of >0,25 m/s
  • Resolution: 0,01 m/s
 

Differential pressure:

  • Measurement range: ±3735 Pa 
  • Accuracy: ±2 % of measurement value or ±0.25 Pa 
  • Resolution: ±0.001 Pa (stat./diff. pressure)
 

Barometric pressure:

  • Measurement range: 47.45 to 135.41 kPa 
  • Accuracy: ±2 % of measurement value 
  • Resolution: 0,133 kPa (absolute pressure)
 

Flow rate:

  • Measurement range hood: 42 to 4250 m³/h 
  • Accuracy: ±3 % of measurement value or ±12 m³/h at flow rate > 85 m³/s 
  • Resolution: 1 m³/h
 

Temperature:

  • Measurement range base system: +4,4 °C to +60 °C
  • Measurement range probe: -10 °C to +60 °C 
  • Accuracy: ±0,3 °C 
  • Resolution: 0,1 °C
 

Relative humidity:

  • Measurement range: 0 to 95 %rH
  • Accuracy: 3 %rH 
  • Resolution: 0,1%rH
 

Data storage: up to 26.500 samples for each parameter with time stamp
Logging interval: user adjustable (10 to 600 s)
Statistik: min, max-, mean value
Interface: USB data cable
Response time: 2 to 8 s
Operating température: +4,4 °C to +60 °C
Dimensions system 8715: 18.8 x 11.4 x 5.8 cm3
Weight: 3.4 kg - measurement system with hood 610 x 610 mm2
Power supply:

  • 4x AA NiMH-batteries or 
  • 4x AA Alkali-batteries or
  • AC-Adpater



Scope of delivery Accubalance 8380:

  • Measurement system DP-CALC Micromanometer Modell 8715 
  • Flow rate measurement hood (610 x 610 mm2) incl. frame-kit 
  • Swirl-X flow conditioner 
  • 1 piece pitot tube 460 mm 
  • 2 pieces static pressure probe 
  • 5 m neoprene tubing 
  • Download software and USB interface cable
  • 4 NiMH-batteries incl. battery holder
  • NIST traceable calibration certification
  • Wheeled luggage-style carrying case
  • Manual