Air capture hood ACCUBALANCE 8380
8380
Packaging Unit:
- Ergonomic design and ultra light weight
- Measurement of the following parameters possible:
- Differential pressure, absolut pressure, volume, flow rate
- Volume / flow rate
- Air speed with sensor at i.e filter surfaces
- Temperature (also in liquids) and relative humidity
- Easy to use software interface
- Battery use
Air capture hood ACCUBALANCE 8380
8380
Packaging Unit:
- Ergonomic design and ultra light weight for easy, one-person operation
- Measurement of the following parameters possible:
- Differential pressure, absolut pressure, volume, flow with pitot tube in a duct
- Volume / flow with hood in air outlets, saftey workbenches
- Air speed with sensor at i.e filter surfaces
- Temperature (also in liquids) and relative humidity
- Easy to use software interface
- Measurement hoods in various sizes
- Display of min-, max- and mean values
- Automatic zero point correction for the pressure sensor
- Battery use
Technical data:
Air speed:
- Pitot tube: 0.125 to 78,0 m/s
- Pressure probe: 0.125 to 25,0 m/s
- Matrix probe: 0.125 to 12,5 m/s
- Accuracy: ±3 % of measurement value or ±0.04 m/s at speed of >0,25 m/s
- Resolution: 0,01 m/s
Differential pressure:
- Measurement range: ±3735 Pa
- Accuracy: ±2 % of measurement value or ±0.25 Pa
- Resolution: ±0.001 Pa (stat./diff. pressure)
Barometric pressure:
- Measurement range: 47.45 to 135.41 kPa
- Accuracy: ±2 % of measurement value
- Resolution: 0,133 kPa (absolute pressure)
Flow rate:
- Measurement range hood: 42 to 4250 m³/h
- Accuracy: ±3 % of measurement value or ±12 m³/h at flow rate > 85 m³/s
- Resolution: 1 m³/h
Temperature:
- Measurement range base system: +4,4 °C to +60 °C
- Measurement range probe: -10 °C to +60 °C
- Accuracy: ±0,3 °C
- Resolution: 0,1 °C
Relative humidity:
- Measurement range: 0 to 95 %rH
- Accuracy: 3 %rH
- Resolution: 0,1%rH
Data storage: up to 26.500 samples for each parameter with time stamp
Logging interval: user adjustable (10 to 600 s)
Statistik: min, max-, mean value
Interface: USB data cable
Response time: 2 to 8 s
Operating température: +4,4 °C to +60 °C
Dimensions system 8715: 18.8 x 11.4 x 5.8 cm3
Weight: 3.4 kg - measurement system with hood 610 x 610 mm2
Power supply:
- 4x AA NiMH-batteries or
- 4x AA Alkali-batteries or
- AC-Adpater
Scope of delivery Accubalance 8380:
- Measurement system DP-CALC Micromanometer Modell 8715
- Flow rate measurement hood (610 x 610 mm2) incl. frame-kit
- Swirl-X flow conditioner
- 1 piece pitot tube 460 mm
- 2 pieces static pressure probe
- 5 m neoprene tubing
- Download software and USB interface cable
- 4 NiMH-batteries incl. battery holder
- NIST traceable calibration certification
- Wheeled luggage-style carrying case
- Manual